CAST
RESIN TRANSFORMERS TAT/R TYPE
|
| |
We have been
manufacturing this type of equipment since 1979 at our works. Up to this
moment we have achieved excellent results among which:
- several
short-circuit tests carried out at CESI's laboratories (Milan) each
one with positive results;
- in 1992,
thanks to CREL (ENEL's Eletrical Research Department) and first company
in Italy to gain this goal, we obtained the Certification for E1 - C1
- F1 classes (in accordance with CEI 14-8 standards). All documentation
pertaining to the above certification can be consulted at our company
head office;
- up to
now more than 7,200 different units have been manufactured and installed
all over the world.
|
| |
 |
TAT/R
transformers series are manufactured by means of modern equipment
and subjected to strict control procedures. After individual testing,
each MT side winding is casted under vacuum by using a special kind
of epoxy resin. The versatility of our production apparatus allows
to obtain a wide range of cast mixtures characterised by different
types of fillers so as to satisfy both different enviromental and
climatic classes and self-extinguishing requirements as well.
|
|
| |
|
Resin
Glass Transition is measured by means
of Differential Scanner Calorimeter after hardening.
|
 |
|
| |
 |
In
order to test the reaction of those transformers to be held in stock
for long periods in low temperatures areas, coils undergo a Thermal
Shock Test inside a special Refrigerating Chamber which can reach
-60ºC temp. values.
|
|
| |
| Impulse
test according to 14-8 Standards performed on a E1 C1 F1 class transformer
supplied by ENEL (National Board for Eletric Power). |

|
|
| |
|
|
Testing
data processing centre:
|
Routine
Partial
discharges
Impulse
Temperature
rise tests.
|
|
MAIN
REFERENCE STANDARDS
-
CEI 14-8 ed. 1992
- CEI 14-12 ed. 1993
- IEC 76 - IEC 726
- VDE 0532
|
|
|
|
| |
|
Self-extinguishing
test performed on a sample coil at CESI laboratories.
|

|
|
| |
|